Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

This article pertains to: IMPACT

Oxygen Saturation Sources (Apps and Devices)

Inform Connected Apps and Devices (see Pulse Oximeter)

Supported Oxygen Saturation Metrics/Data

  • Oxygen Saturation (SpO2) - %

  • Pulse - bpm (beats per minute) 

Oxygen Saturation Goals and Events (Notifications)

Goal and event (notification) options vary by the Impact measurement type. The tables below show goal and notification options for oxygen saturation. 

Goals

Metric

Goal Types

Number of Values

Oxygen Saturation

Threshold, Averaged Threshold, Adherence/Reading Count

Range, Single Value (dependent on goal type)

(info) Control Goal:

The “control goal” is the goal that determines which metrics or readings are in and out of range visually from the clinician dashboard. A single goal of this type must be present within the program in order for dashboard visuals (logbook and charts) to display readings or individual metrics as in or out of range. The “control goal” is added by default when a new program is created with the corresponding measurement type.

“Keep all SpO2 levels greater than or equal to [spo2] %”

Measurement Type: Oxygen Saturation - Blood Oxygen Saturation

Goal Type: Individual Reading Limit

Goal Usage: Reviewer Cannot Disable


Events 

Metric

Trigger Type

Comparison

Recipient

Schedule

Oxygen Saturation

Adherence/Reading Count

Greater than, Less than

Member, Provider

Window

Oxygen Saturation

Individual Reading Limit

Greater than, Less than

Member, Provider

Every time, At most once per day

Oxygen Saturation

Average Reading Limit

Greater than, Less than

Member, Provider

Window

Oxygen Saturation Logbook and Charts

The logbook view and chart views vary by the Impact measurement type. The examples below show the logbook view and chart view for oxygen saturation.


Logbook

The logbook for the oxygen saturation measurement type shows in a compact format, with a range dependent on the view range selected at the top of the clinician dashboard. Both oxygen saturation(SpO2) and pulse (if available) values are shown:

Charts

The chart view for the oxygen saturation measurement type shows a timeline with oxygen saturation (SpO2) data. The chart date range is dependent on the view window selected at the top of the clinician dashboard. The reading value, reading timestamp, and comment (if available) are shown on datapoint click.

  • No labels